The torkel 860 is used for systems ranging from 12 to 480 v, and discharging can proceed at up to 110 a. Provide higher load currents for concurrent power tests. When coupled with the cell voltage logger, bvm, it becomes a comprehensive, standalone, discharge test system. View online or download megger torkel 860 user manual. Works with 12 v to 480 v battery systems and can discharge at up to 110 a 15 kw maximum power.
The file extension pdf and ranks to the documents category. The megger torkel 930 is supplied with a cable set, a soft case for cables, torkel viewer software, a usb memory stick and a carry case. Megger torkel840 torkel860 bs49094 bs49096 telecom. Torkel 820840860 battery load units users manual users manual. The torkel 900 series has been designed to carry out loaddischarge testing. Unit adjusts to include load currents in the test parameters. If higher current is desired, two or more torkel 860 units or extra loads txl can be linked together. Torkel 860 multi is designed primarily for people who travel from place to place to maintain battery systems having different voltages. Discharging can take place at constant current, constant output, constant resistance or in accordance with a preselected load profile. Your megger account allows you to register your equipment for warranty, and access a wide range of support material including software updates and technical documents. Discharging can take place at constant current, constant output, constant resistance or in accordance with a preselected load. Megger programma torkel 860 battery load unit portable 22 kg, 38 kg with accessories and transport case battery discharge load unit.
Torkel 860 is used for systems ranging from 12 to 480 v, and discharging can proceed at up to 110 a. Works with 12v to 480v battery systems and can discharge at up to 110a 15kw maximum power. Torkel 840 860 torkel 840 860 battery load units batteries in power plants and transformer substations must provide the equipment they serve with standby power in the event of a power failure. Buy torkel 900series battery load unit ireland powerpoint. Later, using the torkel win program, you can transfer these readings to your computer for storage, printout or export. If higher current is desired, two or more torkel 860 units or extra load units, txl, torkel 860 and the extra loads txl 870. Together they form a system which can discharge batteries with currents of up to several ka. Discharge testing is the only test method that provides a comprehensive insight into battery capacity, and is therefore an essential part of vigorous battery maintenance programmes. If a higher current is needed torkel systems can be linked together. Works with 12 v to 480 v battery systems and can discharge at up to 110 a 15 kw. External measurement input used to measure current in an external path by. Tests can be conducted at constant current, constant power, constant resistance or in accordance with a preselected load profile.
Programma torkel 840860 battery load units batteries can be tested in service unit adjusts to include load currents in the test parameters user adjustable alarm and shutdown points to avoid excessive discharge easily expandable for larger battery banks using txl extra load units view test parametersresults real time as testing progresses using torkel win. Optional accessory for the pro,torkel840 battery load unit. It is the first of its kind instrument in that the proactiv can download all pre. Megger txl890 has been designed for use with megger torkel battery load testers to provide higher load currents for use in constant current or constant power tests. Megger torkel 950 battery load unit megger torkel950. If your pc is connected to torkel 820 during the test, torkel win builds up a voltage curve on the screen in real time and displays the current, voltage and capacity readings. This makes it an excellent option when conducting discharge tests on the capacity of standby power batteries in. View and download megger torkel 820 user manual online. Txl extra loads are connected directly to the battery, and torkel measures the total current using a clampon ammeter. There are also frequently asked questions, a product rating and feedback from users to enable you to optimally use your product. The torkel 900 is the fourth generation in the series of meggers trusted battery discharge test systems. They are designed for use together with torkel battery load units.
Unfortunately, however, the capacity of such batteries can drop significantly for a number of reasons before their calculated life expectancy is reached. Torkel 820840860 battery tester battery electricity. The torkel 930 offers a convenient and dependable way of determining the true capacity of storage battery. Torkel 820 measuring instruments pdf manual download. Megger txl890 extra load unit for torkel battery test systems. Programma torkel 860 battery load unit precise facilities. Connects in parallel with other torkel systems or other load banks. The torkel 950 is the fourth generation in the series of meggers trusted battery discharge test systems.
The torkel 860 load unit is used to test backup batteries used in substations and power plants where power failures can cause major problems. Discharging can take place at constant current, constant power, constant resistance or in accordance with a preselected load profile. Megger torkel840 torkel860 bs49094 bs49096 telecom battery load discharge tester for ups cells code. Megger torkel 860 multi megger torkel860 battery load unit. Megger torkel840 bs49094 torkel860 bs49096 product datasheet. Megger txl890 load unit for use with torkel systems megger. Specifications are subject to change without notice. Use the download button below or simple online reader. Torkel win 720 with software and prommore down product information. The megger programma torkel 860 is a portable battery discharge load unit. The torkel 860 is designed primarily for people who travel from place to place to maintain battery systems having different voltages.
Atec meggertorkel840860 user guide download pdf for free and without registration. Although performance differs from one model to the next, all models are used in the same way. Battery test equipment intellirent products category. Megger torkel 930 megger torkel930 battery load unit. This manual explains how to use torkel 820, torkel 840 and torkel 860 battery load units, and it also covers the txl830, txl850 and txl870 extra loads. We have 1 megger torkel 860 manual available for free pdf download.
Programma torkel 860 battery loading unit hire inlec. The torkel 930 is used to perform load tests or discharge tests which is the only way to determine a battery systems actual capacity. Adds up to an extra 112a load capacity to a discharge test 15. Their purpose is to provide higher load currents for use in constant current or constant power tests. Together, megger torkel and the txl extra loads form a system that can discharge batteries with currents of up to several ka.
Megger torkel win software bs 8208x building up a voltage curve on screen in real time, the megger torkel win software bs 8208x offers you a useful insight into torkel tests by allowing your readings to be transferred to a pc for storage, printout or export. The torkel 930 can be used for battery systems ranging from 12 to 300 v, frequently encountered in switchgear or similar equipment. It features excellent discharging capacity plus a broad voltage range and outstanding portability a unique combination. Torkel 820840860 battery tester free download as pdf file. If higher current is desired, two or more torkel 860 units or extra load units, txl, can be linked together. With bvm functionality in addition to datareport and safety features, it is an advanced, accurate loaddischarge tester that can provide precise actual battery capacity readings over impressive ranges. Torkel 840860 torkel 840860 battery load units batteries in power plants and transformer substations must provide the equipment they serve with standby power in the event of a power failure. Operates as a slave in combination with a pro,torkel840 battery load unit. This allows the user to determine the battery systems actual capacity. The torkel 860 is used for systems ranging from 12480v with discharging taking place at 110a.